Smoke Alarm Spacing Calculator — BS 5839-6 Compliance
Calculate the number and type of smoke, heat and CO alarms needed for your property under BS 5839-6:2019 and Approved Document B.
Include all storeys (ground = 1)
Average habitable rooms per floor (exc. bathrooms)
BS 5839-6 LD1/LD2 places a heat alarm (not a smoke alarm) in the kitchen
An integral garage takes a heat alarm under LD1/LD2 (applies to houses and HMOs)
Safety notice
Electrical work in dwellings can be notifiable under Part P of the Building Regulations. Treat these figures as planning guidance only: circuits must be designed, installed and certified to BS 7671 by a competent person, normally a registered electrician.
Next up: related pages
How We Calculate This
This calculator determines the number of smoke alarms and heat alarms needed based on your property type, number of floors, and room count. It follows the requirements of BS 5839-6 (Fire detection and fire alarm systems for buildings — Code of practice for the design, installation, commissioning and maintenance of fire detection and fire alarm systems in domestic premises).
Detection levels (categories)
- LD1: Smoke detection in every room and area (except bathrooms, shower rooms and cupboards under 1m²) plus a heat alarm in the kitchen — required for HMOs and for single dwellings of 4+ storeys
- LD2: Smoke alarms in all circulation spaces (one per storey) plus the principal habitable room (one for the dwelling), with a heat alarm in the kitchen — standard for new builds/rewires under 4 storeys
- LD3: Detection in escape routes (circulation spaces) only — the layout broadly matching the England rented/social statutory minimum
System grades
- Grade A: A control-panel-based system to BS EN 54 with mains power and a standby supply — recommended for single dwellings of 4+ storeys and larger HMOs
- Grade D1: Mains-powered alarms with tamper-proof (sealed) integral battery backup, interlinked — required for new builds and rewires
- Grade D2: Mains-powered alarms with user-replaceable battery backup, interlinked
- Grade F: Battery-only alarms (sealed long-life Grade F1, or user-replaceable Grade F2) — can satisfy the England rented/social statutory minimum, though sealed 10-year units are recommended
Carbon monoxide alarms
The Smoke and Carbon Monoxide Alarm (England) Regulations 2022 (and Approved Document J) require a CO alarm to BS EN 50291 in any room used as living accommodation that contains a fixed combustion appliance — a boiler, gas/oil/solid-fuel heater or log burner — but not a gas cooker. CO alarms are separate from the smoke/heat alarm count.
Regulations
This calculator references BS 5839-6:2019, Approved Document B (Fire safety), Approved Document J, and the Smoke and Carbon Monoxide Alarm (England) Regulations 2015 as amended in 2022. The 2022 Regulations apply to private-rented and social-housing dwellings in England (not owner-occupiers) and require at least one smoke alarm on every storey with living accommodation plus a CO alarm where there is a fixed combustion appliance. In Scotland, since February 2022 every home regardless of tenure must have interlinked alarms (smoke in the main living room, smoke in each circulation space, heat in the kitchen). For HMOs, additional requirements may apply under the Housing Act 2004 and local licensing conditions. Always verify requirements with your local Building Control or Fire and Rescue Service.
Frequently Asked Questions
These are categories of fire detection in dwellings defined by BS 5839-6:2019. LD1 provides the highest level of protection — detection in every room and area (except bathrooms, shower rooms and cupboards under 1m²), with a heat alarm in the kitchen. LD2 is the standard for new builds and rewires — smoke alarms in all circulation spaces (one per storey) plus the principal habitable room (the main living room), with a heat alarm in the kitchen; the principal habitable room is a single detector for the dwelling, not one per storey. LD3 is the minimum — detection in escape routes only (hallways, landings, stairways). The Smoke and Carbon Monoxide Alarm (England) Regulations 2022 require at least one smoke alarm on each storey with living accommodation (broadly an LD3 layout) plus a CO alarm where there is a fixed combustion appliance; they do not specify an LD category or mandate a kitchen heat alarm.
For new builds, extensions, and full rewires, yes — smoke alarms must be mains-powered (Grade D1) with integral battery backup and interlinked (when one triggers, they all sound). This is required by Approved Document B and BS 5839-6. For existing rented or social-housing dwellings in England, the Smoke and Carbon Monoxide Alarm Regulations 2022 require at least one smoke alarm on every storey with living accommodation but do not mandate mains power or interlinking, so battery alarms are acceptable — sealed long-life lithium units (10-year battery) are strongly recommended. Those regulations do not apply to owner-occupiers. In Scotland (since February 2022) every home, regardless of tenure, must have interlinked alarms (smoke in the main living room, smoke in each circulation space, heat in the kitchen). For commercial fire alarm systems, see our Fire Alarm Cable Calculator.
Smoke alarms should be mounted on the ceiling, at least 300mm from any wall or light fitting. They should be positioned in the centre of the circulation space (hallway or landing). Do not place smoke alarms in kitchens or bathrooms — use a heat alarm in the kitchen instead. Avoid locations near air vents, extractor fans or areas where steam or cooking fumes could cause false alarms. On a pitched or sloped ceiling, BS 5839-6 requires a smoke alarm to be sited within a maximum of 600mm vertically below the apex; a heat alarm must be within a maximum of 150mm of the apex.
Under BS 5839-6:2019 (Categories LD1 and LD2) and Approved Document B for new builds and rewires, yes — a heat alarm (not a smoke alarm) is placed in the kitchen. Heat alarms respond to temperature rise rather than smoke particles, so they are not triggered by normal cooking. They are also recommended in integral garages. A heat alarm rated to about 58°C (BS EN 54-5 Class A1) is standard for kitchens. Note that the Smoke and Carbon Monoxide Alarm (England) Regulations 2022 do NOT require a kitchen heat alarm — they require at least one smoke alarm per storey with living accommodation and a CO alarm where there is a fixed combustion appliance. A kitchen heat alarm is a BS 5839-6 / Building Regulations recommendation, not a statutory requirement of the 2022 Regulations (in Scotland, however, a kitchen heat alarm is a legal requirement in all homes).
Houses in Multiple Occupation (HMOs) require the highest level of fire detection — LD1, Grade D1. This means a mains-powered, interlinked alarm in every habitable room (bedrooms, living rooms, dining rooms) and every circulation space (hallways, landings, stairways), plus heat alarms in all kitchens. The system must have battery backup. Some local authorities have additional requirements, so always check with your council's housing team. HMOs also require fire doors, emergency lighting and signage.
Related Calculators
Was this calculator helpful?
Last updated: February 2026
Verified against UK standards · estimates only, confirm with your supplier.