UK Building Reference Tables
96 quick-reference tables for UK building materials, dimensions, and standards. Bookmark these for the job site.
Concrete Mix Ratios
Standard UK concrete mix ratios explained with quantities per cubic metre and guidance on when to use each.
Insulation U-Values
Part L target U-values for walls, floors, roofs and windows with insulation thicknesses to achieve compliance.
UK Brick Dimensions
Standard UK brick sizes, coordinating dimensions and bricks per square metre for common bond patterns.
UK Cable Sizes
BS 7671 cable sizes and current ratings for common UK domestic circuits and installations.
UK Plasterboard Sizes
All standard UK plasterboard sizes, thicknesses, weights and types including fire-rated and moisture-resistant boards.
UK Timber Sizes
Standard UK timber sizes in CLS and regularised with metric and imperial equivalents.
UK Pipe Sizes
Standard UK plumbing and heating pipe sizes in copper, plastic and steel.
UK Screw and Fixing Sizes
UK screw gauge sizes, lengths and pilot hole diameters for wood, masonry and metal fixings.
UK Block Sizes
Standard UK concrete block sizes, weights and blocks per m² by type.
Part L 2021 U-Value Targets
Part L 2021 target U-values for all building elements with notional dwelling values.
BS 7671 Domestic Circuit Guide
BS 7671 domestic circuit specifications: cable sizes, MCB ratings and protective devices.
Mortar Mix Ratios
Standard mortar mix ratios for bricklaying, blockwork, rendering and pointing.
Radiator BTU Output Table
Radiator BTU output reference by size and type for heating system design.
Roof Tile Coverage Rates
Roof tile coverage rates per m² by tile type with batten gauge.
Paint Coverage Rates
Paint coverage rates in m² per litre by paint type and surface.
Skip Size Guide
Skip sizes from mini to RoRo with volume, weight limits and typical uses.
Drainage Pipe Sizes and Falls
Drainage pipe sizes and minimum fall gradients for foul and surface water.
Fixings Guide by Wall Type
Fixing types and pull-out loads by wall material: brick, block, plasterboard, timber and concrete.
Part B Fire Resistance Ratings
AD-B fire resistance periods: 30, 60, 90, 120 min ratings by building type for walls, floors, doors and structural elements.
Part B Unprotected Areas
AD-B boundary distance calculations, permitted unprotected areas, and methods 1-4 for external wall fire spread assessment.
Part E Acoustic Ratings
AD-E sound insulation requirements: airborne DnT,w+Ctr and impact L'nT,w targets for separating walls and floors.
Part E Sound Reduction
Part E compliant wall and floor constructions: Robust Details types, Rw ratings, and specifications for separating elements.
Part F Ventilation Rates
AD-F ventilation rates: Systems 1-4, kitchen and bathroom extract rates, background ventilator sizing, and purge ventilation.
Part F Extract Fan Requirements
Part F extract fan sizing by room, noise limits, duct length derating, timer requirements, and humidity sensor options.
Part G Hot Water Standards
AD-G hot water safety: storage at 60°C, TMV max 48°C at bath outlets, Legionella prevention, unvented cylinder G3 notification.
Part H Drainage Gradients
AD-H drainage gradients: minimum falls for foul and surface water pipes, inspection chamber spacing, and bedding classes.
Part J Flue Sizing
AD-J flue sizes by appliance type, terminal positions, clearances from openings, chimney heights, and hearth specifications.
Part K Stair Dimensions
AD-K stair dimensions: max rise 220mm, min going 220mm, pitch max 42°, headroom 2.0m, handrail and guarding heights.
Part L U-Value Targets History
Part L U-value requirements from 2006 to 2021: walls, floors, roofs, windows and doors targets by edition year.
Part L Air Permeability
Part L air permeability: target 8 m³/h.m² at 50 Pa, testing requirements, common leakage paths, and ventilation implications.
Part M Door Widths
AD-M door widths: minimum 775mm clear for new builds, approach spaces, and M4(1) M4(2) M4(3) accessibility categories.
Part M Ramp Gradients
AD-M ramp gradients: max 1:12 for 2m going, 1:15 for 5m, 1:20 for 10m, with landing sizes and handrail heights.
Part O Overheating Limits
AD-O overheating: glazing area limits by orientation, cross-ventilation requirements, shading factors, and TM59 criteria.
Part P RCD Requirements
AD-P and BS 7671 RCD protection: 30mA requirements for socket circuits, bathrooms, outdoors, RCD types, and notification.
Part Q Security Standards
AD-Q security: PAS 24:2016 door and window standards, letter plate specs, and door hardware for new dwellings in England.
Part S EV Charging Requirements
AD-S EV charging: 1 charge point per dwelling with parking, 1 per 5 commercial spaces, 7kW Mode 3 minimum specs.
UK Nail Sizes
Common UK nail types and sizes — round wire, lost head, ring shank, masonry, clout — with gauges, lengths and uses.
UK Anchor Bolt & Wall Plug Sizes
UK wall plug colours and sizes, rawlbolts, sleeve anchors and chemical anchors with drill hole sizes and load ratings.
UK Hinge Sizes
Butt hinges, parliament hinges and rising butt hinges with sizes by door weight and fire door requirements.
UK Joist Hanger Sizes
Standard joist hanger sizes for 47 mm and 75 mm timber with masonry and timber-to-timber types and safe working loads.
UK Timber Connector Sizes
Framing anchors, truss clips, joist straps and restraint straps with sizes, fixing specs and BS EN 14545 references.
UK Plywood & OSB Grades
Structural plywood and OSB grades, thicknesses, moisture classes and applications for UK construction.
UK MDF & Chipboard Sizes
Standard MDF and chipboard sheet sizes, thicknesses, grades including moisture-resistant P5 and applications.
UK Decking Board Sizes
Softwood and composite decking board sizes, profiles, lengths and fixing centres for UK garden decking.
UK Lintel Sizes
Steel lintels, concrete lintels and timber lintels with span tables, bearing requirements and cavity widths.
UK Cavity Tray Sizes
Cavity tray DPC types, widths, weep hole spacing and material specifications for UK cavity wall construction.
UK DPC Specifications
DPC types, widths and placement rules per Approved Document C for UK building construction.
UK Brick Types
Facing, engineering (Class A, B), common, London stock and Fletton bricks with strength and frost resistance.
UK Block Types
Dense, lightweight aggregate and aerated concrete blocks with compressive strengths and thermal conductivity.
UK Airbrick Sizes
Standard airbrick sizes, terracotta and plastic types, ventilation rates and installation requirements.
UK Copper Pipe Sizes
BS EN 1057 copper pipe sizes from 8–54 mm with outside diameters, wall thicknesses and working pressures.
UK Plastic Pipe Sizes
Speedfit, Hep2O, barrier pipe and PEX sizes with copper equivalents and temperature/pressure ratings.
UK Push-Fit Compatibility
JG Speedfit, Hep2O and Polypipe push-fit compatibility guide with sizes, inserts and pressure ratings.
UK Trap Sizes
P-trap, S-trap, bottle trap and running trap sizes for basins, baths, showers and WCs with depth of seal.
UK Soil Pipe Sizes
110 mm, 82 mm and 160 mm soil pipe sizes with connection types, gradient requirements and SVP heights.
UK Guttering Profiles
Half-round, square-line, ogee and deep-flow gutter profiles with sizes, flow capacities and bracket spacing.
UK Circuit Breaker Types
MCB types B, C, D curves, RCBO, RCD types A, AC, F with ratings from 6A–63A per BS 7671.
UK Consumer Unit Sizes
Consumer unit sizes from 6 to 24 ways, split load vs dual RCD vs RCBO board configurations.
UK Cable Trunking Sizes
Mini and maxi trunking sizes with cable fill capacities, compartment options and fixing centres.
UK Conduit Sizes
20, 25 and 32 mm conduit in PVC and galvanised steel with cable fill calculations and bend radius.
UK Insulation Lambda Values
Thermal conductivity (lambda) values for mineral wool, PIR, EPS, XPS, phenolic, wood fibre and natural fibres.
UK Vapour Resistance Values
Vapour resistivity for common building materials: plasterboard, OSB, PIR, breather membranes and VCLs.
UK Tile Adhesive Coverage
Tile adhesive coverage rates by tile size and substrate for walls and floors with notch trowel sizes.
UK Grout Coverage Rates
Grout quantities by tile size and joint width in kg/m² for 100x100 to 600x600 tiles, 2–10 mm joints.
UK Sealant Types
Silicone, acrylic, polyurethane, hybrid and butyl sealant types with cure times and applications.
UK Adhesive Types
PVA, grab, contact, epoxy, construction and tile adhesives with uses, cure times and working temperatures.
Wire Colour Codes — Old vs New
UK wiring colour codes old vs new. Red/black to brown/blue changeover for single-phase and three-phase per BS 7671.
Cable Ampacity Table
Current carrying capacity by cable size, installation method and insulation type per BS 7671 Tables 4D1A-4D5A.
Voltage Drop Coefficients
mV/A/m voltage drop values for common cable sizes per BS 7671 Tables 4D1B-4D5B.
Earth Electrode Resistance
Target earth electrode resistance values for TT systems, soil resistivity by type and testing methods.
BSP Pipe Thread Sizes
BSP parallel and taper thread sizes from 1/8 to 2 inch with TPI, major diameter and tapping drill sizes.
Water Velocity Standards
Maximum water velocities by pipe material for UK plumbing and heating. Noise thresholds and water hammer prevention.
Boiler Flue Temperature Ranges
Flue gas temperatures by boiler type and implications for flue material selection — plastic vs metal.
Joist Span Tables — C16 and C24
Maximum clear spans for C16 and C24 floor joists at 400mm and 600mm centres per TRADA span tables.
Rafter Span Tables
Maximum rafter spans for C16 and C24 timber at common pitches with purlin sizes and roof covering weights.
Beam Deflection Limits
Maximum deflection limits for beams and floors per Eurocodes. L/250, L/360 limits with steel beam section properties.
Notching and Drilling Rules
Joist notching and drilling rules per Approved Document A and BS 8103. Maximum depths, diameters and permitted zones.
Brick Bond Patterns
UK brick bond patterns: stretcher, Flemish, English, English garden wall and stack bond with structural implications.
Mortar Suction Rates
Initial Rate of Absorption targets for brickwork, testing methods, wetting requirements and bond strength effects.
Movement Joint Spacing
Movement joint spacing for clay brick, concrete block and calcium silicate masonry with width and sealant details.
Weep Hole Spacing
Weep hole spacing at DPC and cavity tray levels. Types, positions and maximum spacing for UK cavity walls.
Adhesive Coverage Rates
Coverage rates for tile adhesive, PVA, grab adhesive, wood glue, epoxy and flooring adhesives per m².
Drying Times Between Coats
Drying and curing times for paints, plasters, screeds and concrete. Recoat intervals and full cure times.
Ventilation Rates by Room
Extract ventilation rates by room type per Approved Document F 2021. Intermittent and continuous extract rates.
Duct Sizing Tables
Duct sizes for domestic ventilation by flow rate and velocity. Round, rectangular, flexible vs rigid comparison.
BS 7671 18th Edition Changes
Key changes from 17th to 18th Edition wiring regulations including AFDD, SPD, RCD and EV charging requirements.
Metric to Imperial Length
mm/cm/m to inches/feet/yards conversions with common UK construction lengths in both units.
Metric to Imperial Area
Square metres to square feet, acres to hectares with common UK room sizes in both units.
Metric to Imperial Volume
Cubic metres to cubic feet, litres to UK and US gallons. Common construction volumes in both units.
Metric to Imperial Weight
Kilograms to pounds/stones, tonnes to tons. Common UK construction material weights.
Pressure Unit Conversions
Bar, psi, kPa, mbar and metres head conversions with common UK water and gas pressure references.
Flow Rate Conversions
l/s, l/min, m³/h and gallons/min conversions with common UK plumbing and ventilation flow rates.
Temperature Conversions
Celsius to Fahrenheit conversions with UK plumbing, heating and construction reference temperatures.
Material Density Reference
Density in kg/m³ for concrete, timber, metals, aggregates, insulation, masonry and soils.
BS 5534 Wind Zones
UK wind zones for slating and tiling per BS 5534. Basic wind speed, site exposure and fixing requirements.
Competent Person Schemes
UK competent person schemes for building regulations self-certification: FENSA, Gas Safe, NICEIC, NAPIT, HETAS, MCS.