TradeCalculator.co.uk
Hot Water Cylinder Sizing Calculator — What Size Cylinder Do I Need?
Calculate the correct hot water cylinder capacity for your UK home based on occupants, bathrooms, and usage patterns.
How many people live in the property
Extra headroom on top of the sizing demand. HWA / BS 8558 suggest 10–20% for future-proofing; default 0 as the 45 L/person basis already includes headroom.
Multiplier for per-person daily usage (default 1.0)
Next up: related pages
How We Calculate This
Our hot water cylinder calculator estimates the correct capacity based on the number of occupants and their hot water usage. It follows the Hot Water Association (HWA) sizing method, consistent with BS 8558:2015 (the current UK guide to domestic water services, which superseded the withdrawn BS 6700).
1. Daily hot water demand
Daily demand = Number of occupants × Usage per person per day. The HWA allows 35–45 litres of stored hot water (at 60°C) per person per day. We bias this within the band by bath habit:
- Shower only: ~35 litres per person per day
- Bath & shower: ~45 litres per person per day
- Mostly baths: ~55 litres per person per day
2. Peak simultaneous draw-off
The cylinder must also buffer the busiest period (typically the morning), when several outlets run at once. Using HWA draw-off volumes — a bath is about 60 litres of stored hot water at 60°C (100 litres at 40°C) and a shower roughly 55 litres — we work out the peak simultaneous draw-off, limited by how many bathrooms you have. The cylinder is never sized below this peak.
3. Recommended size
The required stored capacity is the larger of the day's demand and the peak draw-off (plus an optional 10–20% spare-capacity margin for future-proofing, as the HWA suggests). We then round up to the nearest standard UK cylinder size: 90L, 120L, 150L, 180L, 210L, 250L, or 300L — never below 120 litres for an occupied home, the smallest size routinely specified for an unvented install. These align with commonly available products from manufacturers like Megaflo, Heatrae Sadia, and Telford. For a family of four this typically lands at 150–180 litres.
Frequently Asked Questions
A family of 4 with a mix of baths and showers typically needs a 150–180 litre cylinder. If baths are used frequently, go for 180 L. For shower-only households, 120–150 L may be sufficient. Always factor in the number of bathrooms as well. Use our DHW Demand Calculator to work out your household's exact hot water usage.
A vented cylinder is fed by a cold water tank in the loft and works on gravity pressure. An unvented cylinder connects directly to the mains, giving much better water pressure at taps and showers. Unvented cylinders must be installed by a G3-qualified engineer under Building Regulations (Part G3). See our Unvented Cylinder Calculator for mains-pressure cylinder sizing.
Reheat time depends on the cylinder size and boiler output. A 150 L cylinder heated by a 24 kW boiler typically takes 40–55 minutes. An immersion heater (3 kW) takes considerably longer — around 3–4 hours for the same cylinder. System boilers with higher outputs reheat faster — use our Boiler Size Calculator to find the right kW for your property, or our Cylinder Heat-Up Calculator for precise recovery times.
Yes, this is a common upgrade in UK homes. However, you need adequate mains water pressure (minimum 1.5 bar, ideally 2+ bar), a G3-qualified installer, and the work must comply with Building Regulations. Your plumber will also need to fit pressure-relief and expansion vessels.
Standard UK hot water cylinder sizes are 90L, 120L, 150L, 180L, 210L, 250L, and 300L. The most common domestic sizes are 150L and 180L. Larger homes with multiple bathrooms may need 210-300L cylinders.