UK Soil Pipe Sizes & Gradients

110 mm standard, 82 mm and 160 mm soil pipe sizes with connection types, gradient requirements and installation guidance.

Standard Soil Pipe Sizes

Standard Soil Pipe Sizes
Nominal Size (mm)Outside Diameter (mm)ApplicationStandard Lengths
8282.4Waste-only stacks, vent pipes3 m, 4 m
110110Standard soil stack, WC connections3 m, 4 m
160160Large buildings, multiple WCs3 m, 6 m

Connection Types

Connection Types
TypeJoint MethodProsCons
Push-fit (ring seal)Rubber O-ring sealEasy, allows movement, demountableSlightly bulkier sockets
Solvent weldSolvent cement adhesiveNeat, slim profile, rigidPermanent, no movement allowance
Boss connectorStrap-on or solvent bossConnects waste pipes to existing stackMust be correctly positioned

Branch Connection Gradients (Approved Document H)

Branch Connection Gradients (Approved Document H)
Branch TypePipe Size (mm)Permitted GradientMax Length
WC branch11018 to 90 mm/m (1:56 to 1:11)6 m
Basin branch3218 to 22 mm/m (1:56 to 1:45) at 1.7 m1.7 m (unventilated)
Bath/shower branch4018 to 90 mm/m (1:56 to 1:11)3 m (unventilated)
Kitchen sink branch4018 to 90 mm/m (1:56 to 1:11)3 m (unventilated)

Branch Pipe Sizes and Trap Requirements by Appliance

Discharge units (DU) are the measure BS EN 12056-2 uses to size branch and combined waste pipes: each appliance carries a DU value, and where two or more share one run before reaching the stack, the values are added together to check the pipe is large enough. The discharge units below are the System I column of BS EN 12056-2 Table 2, the values this site’s waste pipe calculator uses; branch pipe and trap sizes are from Approved Document H Tables 1 and 2, and the combined-run row is a conservative domestic guide rather than a tabulated figure.

Branch Pipe Sizes and Trap Requirements by Appliance
ApplianceBranch Pipe (mm)Discharge Units (DU)Trap Size (mm)
Wash basin320.532
Bath400.840
Shower400.640
Kitchen sink400.840
Washing machine / dishwasher400.840
Combined run (2+ appliances, no WC)50 minUp to 6Per appliance
WC (toilet)100 (110 OD)2.0100 (110 OD, integral in pan)

Discharge units per BS EN 12056-2 Table 2 System I and branch pipe sizes per Approved Document H Table 2 and paragraph 1.15, as used in the Waste Pipe Sizing Calculator. Where a combined run carries more than 6 DU, step up to 65 mm for 7 to 12 DU, or 75 mm and above for over 12 DU; any WC on the run still requires 100 mm regardless of the other appliances sharing it.

Related Calculators

See the Drainage Pipe Sizes for underground drainage, or the Trap Sizes for waste trap specifications.

Use the Waste Pipe Sizing Calculator to size a branch or combined waste run from your own fixture list, including discharge units, minimum fall and venting.