TradeCalculator.co.uk
Fire Door Specification Calculator — FD30/FD60 Rating per Part B
Determine fire door ratings, ironmongery and intumescent requirements based on UK Building Regulations Approved Document B.
Total storeys including basements
Total fire doors to specify
Escape route doors need additional signage
Fire-rated glazing will be specified if enabled
Calculate total intumescent strip required
Safety notice
Fire safety measures must satisfy Approved Document B and often need building control approval. Confirm the final specification with building control or a fire engineer before relying on it.
Next up: related pages
How We Calculate This
This calculator determines the correct fire door specification based on Approved Document B of the UK Building Regulations, BS 476-22, and BS EN 1634-1. It considers the building type, number of storeys, door location and intended use to recommend the appropriate fire rating, ironmongery and sealing requirements.
How it works
- Building type: Dwellings, flats, HMOs, commercial and care homes each have different fire door requirements under AD B.
- Door location: The position of the door within the building determines the required fire rating. Flat entrance doors, compartment walls and stairway enclosures outside single family houses have the highest requirements. A protected stairway inside a single family dwellinghouse is the exception: Table C1 item 11(b) sets it at minimum E 20 (FD20) with no smoke seal, and item 4a excepts it from the E 30 Sa entry.
- Building height: No row of Table C1 changes with building height. The one height rule in AD B is the firefighting shaft: where a building has a storey more than 18m above fire and rescue service vehicle access level, para 15.2 requires one or more firefighting shafts, and Diagram 15.1 gives that shaft enclosure E 60 Sa (FD 60 S) doorsets. That is the shaft door only. Other protected stairways in the same building stay at E 30 Sa (FD 30 S) under Table C1 item 4a. A typical 4-5 storey block (~12-15m) usually stays at FD30S. Longer periods otherwise reach a door only by inheritance, where a doorset in a compartment wall or floor takes the period of the element it sits in (Table C1 items 1, 2e and 3, via para C13 and Tables B1/B2). Always confirm with building control and the fire strategy.
- Ironmongery: All components must be CE-marked and tested as part of the fire door assembly to BS EN 1634-1.
Key standards
- Approved Document B: Fire safety requirements for buildings in England
- BS 476-22: Fire resistance test for non-loadbearing elements
- BS EN 1634-1: Fire resistance and smoke control tests for doors
- BS EN 1154: Door closing devices specification
Frequently Asked Questions
In a standard 2-storey dwellinghouse (top floor up to 4.5m above ground), fire doors to habitable rooms are generally NOT required under Approved Document B Volume 1 — instead each habitable room (except the kitchen) must have an escape window or external door, or direct access to the protected stairway. Once a floor sits more than 4.5m above ground (3 or more storeys, including a loft conversion that adds a 3rd storey) the stairway must be enclosed and the doorsets onto it need a minimum of E 20 (FD20), not FD30. AD B Vol 1 para 2.21b calls for fire resisting doors (minimum E 20) and partitions (minimum REI 30), and Table C1 item 11(b) rates a doorset forming part of the enclosures to a protected stairway in a single family dwellinghouse at E 20 / FD 20 with no Sa suffix, so no smoke seal is required; Appendix C5c also excepts fire doorsets within a dwellinghouse from the self-closing rule, so no door closer is needed either. FD20 doorsets are no longer manufactured or third-party certified, so an FD30 door is what you buy to satisfy the E 20 minimum, which exceeds the requirement rather than being the requirement. In HMOs all habitable-room doors to common areas must be FD30S, and in flats the E 30 Sa entry at Table C1 item 4a applies. The one fire door needed in a typical 2-storey house is the integral garage door, which must be FD30S with smoke seals and a self-closer (Table C1 item 11a).
FD30 provides 30 minutes of fire resistance (integrity). FD30S adds an "S" for smoke seal, meaning the door includes cold smoke seals that prevent smoke passage at ambient temperatures. Flat entrance doors and HMO room doors require the "S" designation with combined intumescent and smoke seals, and so do doors to a protected stairway in every building type except a single family dwellinghouse: Table C1 item 4a rates "a protected stairway (except as described in item 9 or 11(b) below)" at E 30 Sa, while item 11(b) puts the house stairway doorset at plain E 20 / FD 20 with no Sa suffix. Inside a house the one door that does need the S suffix is the door between the dwelling and an integral garage (item 11a, E 30 Sa). The smoke seal is typically a nylon brush or blade type fitted within the intumescent strip.
All fire door ironmongery must be CE-marked and fire-tested as part of a door assembly. Requirements include: 3 ball-bearing hinges to BS EN 1935 (grade 12, 13 or 14 acceptable where a self-closer is fitted — grade 13 is the common spec), a self-closing device (BS EN 1154, though AD B Vol 1 Appendix C5c excepts fire doorsets within flats and dwellinghouses, so an internal house door takes no closer while the door to an integral garage still does), intumescent strips in the frame or door edge, a fire-rated lock or latch (BS EN 12209), and signage (Fire Door Keep Shut to BS EN ISO 7010 / BS 5499-4). Letterplates are generally not permitted unless fire-rated to BS EN 13724. All items must be fitted per the door manufacturer's installation instructions.
Yes, all fire doors require intumescent strips to seal the gap between door and frame during a fire. The intumescent material expands when heated to approximately 200 degrees C, sealing gaps and preventing fire and smoke passage. Standard sizes are 10mm x 4mm for FD30 doors and 15mm x 4mm for FD60 doors. They are fitted into a groove in either the door edge or the frame rebate. Some locations also require a combined intumescent and cold smoke seal.
Yes, but the glazing must be fire-rated to match the door rating. For FD30 doors, Georgian wired glass (6mm) or proprietary fire-rated glass such as Pyran S or Pyroguard can be used. The maximum glazed area is typically 0.5 square metres unless the manufacturer has test evidence for larger panes. The glazing beads must incorporate intumescent backing strips. All glazed fire doors must be tested as complete assemblies to BS 476-22 or BS EN 1634-1.
Was this calculator helpful?
Last updated: March 2026