TradeCalculator.co.uk
Skirting Board Calculator — Boards, Corners & Fixings
Calculate skirting board lengths, corners, adhesive and fixings for any room. Uses standard UK board lengths.
Longest dimension of the room
Shortest dimension of the room
Standard doorway = 0.8m wide
Standard room = 4 internal corners
e.g. chimney breast, bay window — adds ~0.3m mitre waste each
Adds 10% extra for mitre cuts and joins
10% recommended for most rooms
Enter your board price for a cost estimate
Default: 0.8m standard doorway
Default: ~10m per 310ml tube (EVO-STIK 15.5m, Everbuild Instant Nails ~11m)
Default: 500mm (skirting is fixed into studs at ~400–600mm centres)
Next up: related pages
How We Calculate This
Our skirting board calculator works by calculating the effective perimeter of your room (total perimeter minus doorway openings), then dividing by the board length to determine how many boards you need. We also calculate adhesive, caulk and fixings.
The formula
Effective perimeter = Total perimeter - (Number of doorways × 0.8m)
Boards needed = (Effective perimeter × (1 + Wastage %)) ÷ Board length
For example, a 4m × 5m room (18m perimeter) with 2 doorways: 18 − (2 × 0.8) = 16.4m. With 10% wastage: 16.4 × 1.10 = 18.04m ÷ 2.4m = 8 boards (rounded up).
Fixings calculation
- Adhesive: 1 tube (310ml grab adhesive) per ~10m of skirting — a conservative figure (EVO-STIK Skirting Board Adhesive covers 15.5m at a 5mm bead; Everbuild Instant Nails ~11m at a 6mm bead). Editable in advanced options.
- Caulk: 1 tube per ~10m for sealing the top edge to the wall (typical decorators caulk gives ~11m at a 6mm bead per 300ml cartridge)
- Pins/nails: roughly every 500mm (~2 per metre). Skirting is fixed into the timber studs at ~400–600mm centres; adjust the spacing in advanced options.
Standard UK board lengths
- 2.4m: Most common, easy to transport
- 3.0m: Good for longer walls, fewer joints
- 4.2m: Longest standard length, minimises joints
Frequently Asked Questions
Standard UK skirting board lengths are 2.4m (8ft), 3.0m (10ft) and 4.2m (14ft). 2.4m is the most common and widely available at B&Q, Screwfix, Wickes and timber merchants. MDF skirting suppliers (such as Skirting World and Howdens) typically stock 3.0m and 4.2m as standard, with 2.4m on request. Longer lengths reduce joints but are harder to transport. This skirting board quantity calculator works with all standard lengths, plus a custom length option.
Modern skirting is most commonly fixed with grab adhesive (such as Sticks Like or No More Nails) applied in a zigzag pattern to the back of the board, then pressed firmly against the wall. For extra security, use lost-head nails or a brad nailer every 400-600mm. On uneven walls, pin and adhesive together give the best result. Fit skirting after your floor covering is down.
Skirting boards should be fitted after your floor covering is installed. For laminate and vinyl flooring, skirting covers the expansion gap — see our Laminate Flooring Calculator or Vinyl Flooring Calculator. For carpet, skirting is fitted before the carpet so the carpet tucks under — work out carpet, underlay and gripper quantities with our carpet calculator. For tiles, fit skirting after tiling — see our Floor Tile Calculator.
Internal corners are where two walls meet going inwards (like the corners of a standard rectangular room — 4 internal corners). External corners are where walls meet going outwards (like a chimney breast or a wall that protrudes into the room). Internal corners are scribed (coped) for a tight fit — the general wastage allowance covers this offcut. External corners are mitred at 45 degrees, which wastes a triangular offcut from the board end, so this calculator adds roughly 0.3m of extra board length per external corner you enter.
Yes, exactly. Enter the room's overall length and overall width as if it were a full rectangle, or switch the input method to enter the perimeter directly. Cutting a notch out of a corner does not change the perimeter: the two walls of the notch simply take the place of the wall sections they replace, so an L-shaped room needs exactly the same run of skirting as its bounding rectangle. Do update the corner counts though: a plain L-shaped room has 5 internal corners and 1 external corner (the corner that points into the room), so the extra mitre waste is allowed for. A chimney breast is different: it adds run rather than removing it. Add the depth of the breast to your room length measurement (the calculator doubles the length, which covers both return sides), then count 2 extra internal and 2 extra external corners for it. Doorways are handled by the separate doorway field, so do not subtract them from your measurements.
MDF skirting board is cheaper, comes pre-primed, and is consistent and easy to work with. It is the most popular choice for modern UK homes. Solid timber (softwood pine) skirting is more traditional, can be stained, and is harder-wearing. For painting, MDF is excellent. For staining or a natural finish, use solid timber. MDF should not be used in damp areas. For decking timber outdoors, see our Decking Calculator.
Related Calculators
Was this calculator helpful?
Last updated: July 2026
Verified against UK standards · estimates only, confirm with your supplier.