Fire Escape Route Calculator — Check Compliance with Approved Document B
Check whether your escape route distances, corridor widths, and number of exits comply with UK fire safety regulations. For dwellings, flats and HMOs.
Total number of floors in the building
People served by the escape route on the busiest storey. Drives the AD B Vol 2 width and exit tables (assessed per storey, not whole building).
Longest actual travel distance (measured along the route, not straight-line). For a flat this is the common-corridor distance from the flat entrance door to the stair (AD B Vol 1 Table 3.1: 7.5 m one-way / 30 m two-way); the separate within-flat 9 m limit is shown in the guidance. Not used for a single dwellinghouse — houses are judged on storey height.
Clear width of the common escape corridor (flats/HMOs). Checked against AD B Vol 2 — not applicable inside a single house.
Two-way escape — applies the alternative-directions travel-distance limit (more permissive)
Next up: related pages
How We Calculate This
This calculator checks an escape-route design against Approved Document B (Fire Safety) and BS 9991 for residential buildings. It is a planning aid — not a substitute for a fire-risk assessment or Building Control sign-off — and covers travel distances, common escape-route widths, the number of exits, and fire-door provisions.
Travel distances
- Dwellinghouse: no horizontal travel-distance limit in Approved Document B Volume 1 — escape is governed by storey height (protected stairway where a floor is more than 4.5 m above ground; escape windows to first-floor rooms in a two-storey house up to 7.5 m).
- Flat: two separate limits — within the flat, 9 m from any habitable room to the flat entrance door (Diagram 3.3, a single maximum with no alternative-directions variant); in the common corridor, 7.5 m where escape is in one direction (dead-end) and 30 m where escape is possible in more than one direction (Table 3.1). This tool checks the common-corridor figure and reports the within-flat 9 m as guidance.
- HMO: 9 m single direction is a LACORS risk benchmark (18 m with alternative directions), not a hard pass/fail limit.
Escape-route width (Approved Document B Volume 2, Table 2.3)
These apply to common escape routes in buildings other than dwellings (flats and HMOs), not inside a single house. Width is set by the number of people served:
- up to 60 people: 750 mm
- up to 110 people: 850 mm
- up to 220 people: 1050 mm
- over 220 people: 5 mm × number of people (the 5 mm/person rule applies only above 220 people; never below 1050 mm)
Number of exits (Approved Document B Volume 2, Table 2.2)
Assessed per room, tier or storey occupancy, not by whole-building total. Table 2.2 has three bands:
- up to 60 people: 1 escape route
- up to 600 people: 2 escape routes
- more than 600 people: 3 escape routes
References
- Approved Document B — Fire safety, Volume 1: Dwellings (2019 edition, incorporating 2020 and 2022 amendments)
- Approved Document B — Fire safety, Volume 2: Buildings other than dwellings (same edition)
- BS 9991:2024 — Fire safety in the design, management and use of residential buildings (supersedes BS 9991:2015)
- LACORS Housing — Fire Safety Guidance (2008), for HMOs
Frequently Asked Questions
No. Approved Document B Volume 1 does not control a single dwellinghouse with a horizontal travel-distance figure — it controls by storey height. A house with a floor more than 4.5 m above ground level must have a protected stairway running the full height of the building; a two-storey house up to 7.5 m can instead rely on escape windows to first-floor habitable rooms (clear openable area at least 0.33 m², at least 450 mm high and 450 mm wide, cill no more than 1100 mm above the floor). The widely-quoted 9 m figure is the FLAT internal limit (door of any habitable room to the flat entrance door, single direction), not a house limit.
There are two separate limits. Within an individual flat, the maximum travel distance from any point in any habitable room to the flat entrance door is 9 m (Approved Document B Volume 1, paragraph 3.18 and Diagram 3.3) — this is a single maximum and does not have a more-permissive "alternative directions" variant. In the common corridor outside the flats (AD B Vol 1 Table 3.1), escape in one direction only (a dead end) is limited to 7.5 m, extending to 30 m where escape is possible in more than one direction. Distances are measured along the actual route, not in a straight line.
In a dwellinghouse with a floor more than 4.5m above ground (3 or more storeys, including a loft conversion), fire doorsets are required to the habitable rooms that open onto the protected stairway (hallway, landing and stairway), and the stairway must be enclosed as a protected route from top to bottom. The minimum is E 20 (FD20), not FD30: Approved Document B Vol 1 Table C1 item 11(b) rates a door forming part of the enclosures to a protected stairway in a single family dwellinghouse at E 20, and the E 30 Sa (FD30S) entry at item 4a expressly excepts that case, so no cold smoke seal is required. Appendix C para C5c also exempts fire doorsets within a dwellinghouse from self-closing devices, so no closer is needed on those doors; the door between the house and an integral garage is the one that does need FD30S with a closer. E 20 is the current requirement and only the product changed: FD20 doorsets are no longer third-party certified, so an FD30 door is what you buy to satisfy the E 20 minimum.
Flat entrance doors must be FD30S — a 30-minute fire door with cold-smoke seals (the S suffix indicates smoke seals). This applies to all flats regardless of the number of storeys, and the door must be fitted with a self-closing device so it shuts automatically.
For common escape routes in buildings other than dwellings (the relevant rule for flats and HMOs), Approved Document B Volume 2 sets the minimum clear width by the number of people it serves: up to 60 persons 750 mm, up to 110 persons 850 mm, up to 220 persons 1050 mm, and over 220 persons 5 mm per person (never less than 1050 mm). For example, a route for 300 people needs 300 × 5 = 1500 mm. These are non-dwelling provisions and do not apply inside a single house, where the hallway/landing simply needs to be a usable protected route.
An HMO (House in Multiple Occupation) is a property rented to 3 or more people forming 2 or more households who share facilities. HMO fire safety is risk-assessed using the LACORS Housing — Fire Safety Guidance (2008): a 9 m single-direction travel distance is treated as a benchmark beyond which additional risk should be assessed and mitigated, rather than an absolute pass/fail limit. Typical provisions include FD30S fire doors to bedrooms and kitchens, a Grade D LD2 interlinked smoke and heat alarm system, and emergency lighting in common areas.