TradeCalculator.co.uk
What Is Part B? — Fire Safety Regulations
A plain-English guide to Part B of the Building Regulations: fire safety, means of escape, fire stopping, compartmentation, and compliance in England.
Definition
Part B (Approved Document B: Fire Safety) is the section of the Building Regulations for England that sets out requirements for fire safety in and around buildings. It covers means of warning and escape, internal fire spread (linings and structure), external fire spread, and access and facilities for the fire service. Part B is divided into Volume 1 (dwelling houses) and Volume 2 (buildings other than dwellings).
When Is It Used?
Part B applies to all new buildings and most building work including extensions, loft conversions, material alterations, and changes of use. It is particularly critical for loft conversions (which create a new storey), HMO conversions, garage-to-house connections, and any work involving party walls or compartment floors. Fire safety is also reviewed during completion inspections by Building Control.
Key Facts
- Interlinked smoke alarms on every storey are mandatory in all new builds and conversions since June 2022
- Fire doors are rated FD20 (20-minute) or FD30 (30-minute) depending on location
- Party walls between houses must provide 60-minute fire resistance
- Surface spread of flame: Class 0 or Class B-s3,d2 (Euroclass) for walls and ceilings in escape routes
- Fire stopping is required at all penetrations through compartment walls and floors
- Escape windows must have a minimum clear opening of 450 x 450 mm with sill max 1100 mm above floor
- Buildings over 11 metres: combustible cladding materials banned (Regulation 7 amendment)
- Carbon monoxide alarms required in rooms with fixed combustion appliances (except gas cookers)
Related Calculators
Use the Fire-Rated Plasterboard Calculator for fire-resisting constructions, or the Smoke Alarm Spacing Calculator for alarm placement. The Fire Door Specification Calculator helps specify the correct fire door ratings.
Next up: related pages
How We Calculate This
Frequently Asked Questions
For a typical two-storey house, Part B requires: interlinked smoke alarms on every storey (mains-wired with battery backup since June 2022), 30-minute fire resistance between the garage and habitable rooms, and adequate means of escape from every habitable room. Under AD B Vol 1 para 2.2, where no floor is more than 4.5m above ground, each habitable room other than the kitchen needs either an emergency escape window or external door, or direct access to a protected stairway. Fire doors are not required on that escape route in a two-storey house.
Fire doorsets are required between an integral or attached garage and the house (E 30 Sa, sold as FD30S, per AD B Vol 1 Table C1 item 11a), and on the doorsets enclosing a protected stairway, including the protected route created by a loft conversion (para 2.21b). In a single-family house those stairway doorsets are minimum E 20 only (Table C1 item 11b), with no cold smoke seal and no self-closing device: Appendix C5 requires a self-closer on the garage door and flat entrance doors, not on fire doorsets within a dwellinghouse. FD20 doorsets are no longer certified as products, so an FD30 door is what you buy to satisfy an E 20 requirement.
Compartmentation divides a building into fire-resisting compartments to limit fire spread. In domestic buildings, this mainly applies to party walls (providing 60-minute fire resistance between attached houses), floor/ceiling assemblies in flats (60-minute between dwellings), and the garage-to-house separation (30-minute). All service penetrations through compartment walls and floors must be fire-stopped.
A loft conversion creating a new storey above 4.5m requires the full escape route to be addressed (AD B Vol 1 para 2.21): a protected stairway from the loft to the final exit with fire-resisting doors (minimum E20/FD20) and partitions (minimum REI 30), interlinked smoke detection on all levels, and fire separation between the loft and the rest of the building. Where that protected stairway is provided, no escape window is required in the loft room itself. An escape window (minimum 0.33 m², at least 450 mm wide and high, bottom of the openable area no more than 1100 mm above floor level) is only required under the para 2.23 open-plan alternative, where sprinklers protect the open floor and the window sits on the first storey rather than in the loft room.
Yes. Following the Grenfell Tower tragedy in 2017 and the Hackitt Review, significant changes have been made. The Building Safety Act 2022 introduced a new Building Safety Regulator for higher-risk buildings (over 18 metres or 7 storeys). Combustible cladding materials are banned on buildings over 11 metres. A new gateway approval process applies to high-rise residential buildings, with stricter documentation requirements at design, construction, and completion stages.
Was this calculator helpful?
Last updated: March 2026
Verified against UK standards · estimates only, confirm with your supplier.