TradeCalculator.co.uk
Pressure Unit Conversions — Bar, PSI, kPa
Pressure unit conversions for UK plumbing, heating and gas installations. Bar, psi, kPa, mbar, metres head and mmHg with common reference values.
Pressure Conversion Table
| Unit | bar | psi | kPa | mbar | m head |
|---|---|---|---|---|---|
| 1 bar | 1 | 14.504 | 100 | 1,000 | 10.2 |
| 1 psi | 0.06895 | 1 | 6.895 | 68.95 | 0.703 |
| 1 kPa | 0.01 | 0.1450 | 1 | 10 | 0.102 |
| 1 mbar | 0.001 | 0.01450 | 0.1 | 1 | 0.0102 |
| 1 m head | 0.0981 | 1.422 | 9.81 | 98.1 | 1 |
Common UK Pressure Reference Values
| Application | Typical Pressure | In bar | In psi |
|---|---|---|---|
| Mains water (min at stop tap) | 10m head | 1.0 | 14.5 |
| Mains water (typical) | 20-40m head | 2-4 | 29-58 |
| Combi boiler DHW | — | 1-3 | 14.5-43.5 |
| Sealed heating system | — | 1.0-1.5 (cold) | 14.5-21.8 |
| Sealed system PRV setting | — | 3.0 | 43.5 |
| Natural gas (domestic) | 21 mbar | 0.021 | 0.30 |
| LPG (regulated) | 37 mbar (propane) | 0.037 | 0.54 |
| Gas soundness test | 30 mbar | 0.030 | 0.44 |
| Tyre pressure (car) | — | 2.0-2.5 | 29-36 |
| Atmospheric pressure | 760 mmHg | 1.013 | 14.70 |
Related Pages
See the Flow Rate Conversions, the Water Velocity Standards, and the UK Pipe Sizes.
Next up: related pages
Frequently Asked Questions
UK mains water pressure typically ranges from 1 to 5 bar, with most properties receiving 2-4 bar. Water companies are required to provide a minimum of 1 bar (10m head) at the external stop tap. Pressure can vary during the day — it is usually highest overnight and lowest in early morning and early evening when demand peaks. Pressure above 5 bar may require a pressure reducing valve (PRV) to protect appliances.
Natural gas is supplied to UK domestic properties at 21 mbar (approximately 0.021 bar or 8.4 inches water gauge). This is measured at the meter. The working pressure at appliances should be 19.5-21.5 mbar. Gas pressure testing is done at higher pressures: 300mm water gauge (approximately 30 mbar) for soundness testing of low-pressure installations. Only Gas Safe registered engineers may work on gas systems.
1 metre head is the pressure exerted by a column of water 1 metre high, equal to approximately 0.098 bar or 9.81 kPa. It is commonly used in plumbing for calculating the static pressure from a cold water tank in a loft — a tank 10m above a tap provides approximately 1 bar of pressure. Pump performance curves also use metres head to show the relationship between flow rate and pressure.
Was this calculator helpful?
Last updated: April 2026
Verified against UK standards · estimates only, confirm with your supplier.