Roof Window Sizing Calculator — What Size Velux Do I Need?
Estimate the size and number of VELUX or roof windows for a loft room using a daylighting rule of thumb, and check whether Part B escape provision is likely to apply.
Measured floor area of the room
Next up: related pages
How We Calculate This
This calculator estimates the size and number of roof windows for a loft room from the room floor area and room type. It applies a daylighting rule of thumb and then picks the smallest standard VELUX size that meets it, before prompting you to check Approved Document B escape provision.
The method
Target glazing area = Floor area × Glazing fraction (1/6 for habitable rooms)
Window size = smallest VELUX size whose effective daylight area meets the target (or the fewest of the largest size if no single window is big enough).
Is the 1/6 figure a regulation?
No. England’s Building Regulations set no minimum daylight glazing area — Part L sets fabric U-values and Part O sets glazing maxima for overheating, but neither sets a minimum. The 1/6 (habitable) and 1/8 (bathroom) ratios are widely-used good-practice rules of thumb, not a clause from any current standard. For a rigorous assessment use BS EN 17037:2018+A1:2021 (daylight-factor / illuminance method). Scotland is the only UK nation with a statutory ratio: 1/15 of floor area (Scottish Technical Handbook s.3.16).
Glazing fractions (rules of thumb)
- Habitable rooms (bedroom, living, kitchen, study): ~1/6 of floor area
- Bathrooms: ~1/8 of floor area
Standard VELUX sizes (effective daylight area)
- CK02: 550 × 780mm — 0.22 m²
- MK04: 780 × 980mm — 0.47 m²
- MK06: 780 × 1180mm — 0.59 m²
- SK06: 1140 × 1180mm — 0.95 m²
- UK08: 1340 × 1400mm — 1.40 m²
Areas are VELUX’s published effective daylight areas (the glass area that admits light), not the larger geometric pane area.
Standards
Daylighting good practice: BS EN 17037:2018+A1:2021 (Daylight in buildings). Emergency escape windows: Approved Document B Vol 1 §2.10 (openable area ≥ 0.33 m², no dimension < 450mm, bottom of openable area ≤ 1100mm above floor). Roof-window installation: follow the manufacturer’s fitting instructions (e.g. VELUX) together with BS 5534:2014+A2:2018 (slating and tiling — code of practice) for the roof-covering interface. Note BS 8213-4 (survey and installation of windows and external doorsets) does notapply to roof windows or rooflights — its scope is limited to windows installed vertically into the external face of a building. England’s Part L sets glazing U-values, not daylight area.
Frequently Asked Questions
There is no statutory minimum in England — the Building Regulations set glazing U-values (Part L) and overheating maxima (Part O), but no minimum daylight area. The widely-used good-practice rule of thumb is glazing of about 1/6 of the floor area for a habitable room (1/8 for a bathroom). For a 12 m² loft bedroom that suggests roughly 2 m² of glazing. For a robust daylight assessment use the current standard, BS EN 17037:2018+A1:2021, which uses daylight-factor or illuminance modelling rather than a flat ratio. Note that Scotland does have a statutory rule of 1/15 of floor area. Separately, a loft bedroom (or other habitable room above the ground floor) usually needs a Part B escape window — a clear opening of at least 0.33 m² with no dimension less than 450mm.
Velux windows come in a range of standard sizes identified by a two-letter code. Common sizes include: CK02 (550x780mm), MK04 (780x980mm), MK06 (780x1180mm), SK06 (1140x1180mm), and UK08 (1340x1400mm). The first letter indicates width (C=550mm, M=780mm, S=1140mm, U=1340mm) and the numbers indicate height. Multiple windows can be combined side-by-side or stacked vertically for larger openings.
This calculator sizes the window only — it does not select a flashing kit — but as a guide, VELUX flashings are coded by the roof covering. EDL suits slate and flat coverings up to 8mm thick (pitch 15°–90°). EDW suits profiled or interlocking tiles with a profile up to 120mm (pitch 15°–90°). EDP suits flat interlocking (plain) concrete or clay tiles. EDN (slate) and EDJ (tile) are recessed kits that let the window sit lower in the roof (pitch 20°–90°). Always confirm the kit against your exact roof covering, profile depth and pitch using VELUX's current fitting guidance and the window's minimum pitch (most centre-pivot windows are 15° minimum).
In most cases, roof windows can be installed under Permitted Development rights without planning permission, provided: the window does not project more than 150mm beyond the existing roof plane; it is not on the front elevation in a conservation area; and the glass is obscure-glazed and non-opening if it overlooks a neighbour (side elevation). However, if you are creating a new habitable room in the loft, you will likely need Building Regulations approval regardless of planning.
If the loft room is a habitable room (bedroom, study, etc.) and there is no alternative protected route to a final exit, Approved Document B Vol 1 §2.10 requires an emergency escape window. The window must have an unobstructed openable area of at least 0.33 m², with no dimension less than 450mm, and the bottom of the openable area must be no more than 1100mm above the floor. Approved Document B sets no lower limit — the 600mm/800mm figures sometimes quoted are guarding (fall-protection) thresholds under Part K, not part of the escape rule. Most VELUX centre-pivot windows in size MK04 and larger meet the openable-area minimum when opened to the escape position.