Natural Light Calculator — Glazing Ratio & Daylight Factor
Estimate the glazing-to-floor ratio, an indicative BS EN 17037 daylight factor and the BRE limiting room depth, with an Approved Document O overheating prompt. England & Wales set no mandatory glazing-to-floor minimum — this is design guidance, not a compliance check.
Total floor area of the room
Total glazed area of all windows in the room (glass only, not frames)
Distance from window wall to back of room (BRE limiting-depth check)
Visible-light transmittance of the glazing (rule of thumb: ~0.6 for double glazing)
Divisor in the simplified daylight-factor rule of thumb (default 2)
Height of window head above floor (default 2.1 m). Depth rule uses head minus 0.85 m working plane.
Next up: related pages
How We Calculate This
This calculator gives three quick natural-light indicators: the glazing-to-floor ratio (a sizing rule of thumb), a rough indicative daylight factor compared to BS EN 17037 targets, and the BRE limiting room depth. It also prompts the Approved Document O overheating check for new dwellings.
Glazing-to-floor ratio (rule of thumb)
England & Wales Building Regulations set no mandatory glazing-to-floor minimum for daylight. We compare your ratio against a selectable guidance reference — Scotland’s 1/15th (6.7%) by default, with the historic 1/10th and the non-mandatory ADL1A 2010 1/20th also available. Bathrooms have no recommended minimum.
Daylight factor estimate
We provide a crude daylight-factor estimate from window area, floor area and an assumed transmittance of 0.6 for double glazing, then compare it to the BS EN 17037 UK National Annex per-room median target (bedroom 0.7%, living room 1.1%, kitchen 1.4%). This is an approximation only: an accurate average daylight factor uses total internal surface area, surface reflectances, the angle of visible sky and a maintenance factor, and detailed assessment uses 3D modelling.
Overheating (Approved Document O)
We flag a large glazing area (above roughly 18% of floor) as an overheating prompt rather than a pass/fail. AD O’s simplified method limits glazing by orientation and cross-ventilation, so a new dwelling needs a full Part O assessment — especially with large south or west-facing glazing.
Room depth
The BRE limiting-depth rule of thumb is 2.5 × (window-head height − 0.85 m working plane). Rooms deeper than this may need roof lights or higher windows.
References
- BS EN 17037:2018 (incl. UK National Annex) — Daylight in buildings
- Approved Document O (2021, for use in England) — Overheating
- Scotland Building Standards Technical Handbook (Domestic), Standard 3.16 — Natural lighting (glazing ≥ 1/15th of floor area)
- BRE — average daylight factor and limiting-depth daylighting rules of thumb
Frequently Asked Questions
In England and Wales there is no mandatory glazing-to-floor ratio for daylight in the Building Regulations — daylight adequacy is assessed using BS EN 17037 daylight-factor or illuminance methods. Scotland’s Technical Handbook does set a rule: habitable rooms and kitchens should have glazing of at least 1/15th (about 6.7%) of the floor area. Older guidance used larger fractions (the historic model byelaw was 1/10th, and ADL1A 2010 non-mandatory guidance noted glazing “much less than 1/20th” may give poor light). A common rule of thumb for a 15 m² room is therefore around 1 m² of glazing at 1/15th, but this is guidance, not a legal minimum.
The glazing-to-floor area ratio is the total glazed window area divided by the room floor area, expressed as a percentage. For example, 3 m² of windows in a 15 m² room gives a ratio of 20%. There is no England/Wales legal minimum; Scotland’s guidance is 1/15th (6.7%). Note that the ratio is a sizing rule of thumb only and does not by itself prove a room is well daylit — obstructions, orientation and room depth all matter.
Approved Document O (Overheating) was introduced in 2021 (in force from June 2022) and applies to new residential buildings in England. It limits solar gains, which is most relevant for south and west-facing rooms with large glazing. Its simplified method does not use a single percentage: it caps the maximum glazing area by orientation and by whether the dwelling has cross-ventilation — broadly in the region of 11–18% of floor area for high-risk single-aspect rooms. A new dwelling generally needs a full Part O assessment; large glazing on south/west elevations is the main trigger for mitigation such as solar shading or larger openable areas.
The daylight factor is the ratio of indoor to outdoor illuminance under a standard overcast sky, expressed as a percentage. BS EN 17037:2018 replaced the old single average-daylight-factor approach; its UK National Annex gives per-room median daylight-factor targets of about 0.7% for bedrooms (100 lux), 1.1% for living rooms (150 lux) and 1.4% for kitchens (200 lux), achieved over 50% of the room. The daylight factor shown by this tool is a rough rule-of-thumb estimate, not an EN 17037 compliance result — an accurate average daylight factor uses total room surface area, surface reflectance and a maintenance factor (the BRE/CIBSE method).
A BRE rule of thumb is that the daylit depth of a room is roughly 2.5 × (window-head height − working-plane height), where the working plane is taken at about 0.85 m above the floor in dwellings. For a window head at 2.1 m this gives about 2.5 × (2.1 − 0.85) ≈ 3.1 m of well-daylit depth. Rooms deeper than this tend to have poor daylight at the back and benefit from higher window heads, roof lights or light wells.
Related Calculators
Was this calculator helpful?
Last updated: June 2026
Verified against UK standards · estimates only, confirm with your supplier.