ACO Drain Calculator — How Many Channel Drain Lengths Do I Need?
Calculate ACO-style channel drain components including channel lengths, end caps, corners, outlets, gratings and sump units to BS EN 1433.
Total linear length of channel drain
90-degree corners in the drain run
Rule of thumb: ~1 outlet per 10–15m, or at the lowest point. Actual capacity depends on catchment area and rainfall (AD H3).
Price per metre of channel for cost estimate
Length of each channel unit (default 1m)
Number of end caps for the system (default 2)
Next up: related pages
How We Calculate This
This calculator determines the components needed for a linear channel drainage system based on your total run length, corner and outlet requirements.
The formula
Channel lengths = ceil(Total run length / 1m)
Standard ACO-style channel drain units are 1 metre long. The total run length is divided by 1m and rounded up to determine the number of channel units needed.
Components calculated
- Channel lengths (1m): The main channel body units
- End caps: 2 per system (one at each dead end)
- Corner units: Special units for 90-degree bends
- Outlet units: Connect the channel to underground drainage
- Sump units: Debris/silt collection at each outlet
- Grating positions: One per channel unit plus one per corner unit. Note: standard ACO channel and corner units are supplied complete with a black plastic grating, so you only order gratings separately if upgrading to galvanised steel or cast-iron tops.
Standards
Channel drainage systems must comply with BS EN 1433 (Drainage channels for vehicular and pedestrian areas) which defines loading classes from A15 to F900. The installation should also comply with Part H of the Building Regulations for connection to the drainage system.
Frequently Asked Questions
ACO is a leading brand of linear channel drainage system. 'ACO drain' has become a generic term (like 'Hoover') for any linear channel drain. These are narrow channels set into the ground surface with removable gratings, used to collect surface water across driveways, patios, garage thresholds, and commercial premises. Other manufacturers include Birco, Hauraton, and Clark Drain.
The loading class depends on the traffic the drain will carry. Class A15 (1.5 tonne) is suitable for pedestrian and garden areas. Class B125 (12.5 tonne) is needed for domestic driveways and car parks where cars will drive over the drain. Class C250 (25 tonne) is for commercial areas with occasional HGV access. Class D400 (40 tonne) is for roads and areas with regular HGV traffic.
ACO channel drains should be set on a minimum 100mm concrete bed (C20/25 mix) with 100mm concrete haunching on each side. The grating level should be 3–5mm below the surrounding surface level to ensure water flows into the channel. The channel should have a minimum fall of 1:100 towards the outlet or sump unit. Use our Drainage Gradient Calculator to check falls.
As a general rule, provide one outlet for every 10-15 metres of channel run, or at the lowest point of the installation. For a driveway threshold, a single outlet at one end is usually sufficient. For longer runs, additional outlets prevent the channel from being overwhelmed during heavy rain. Each outlet needs a trapped gully or connection to the surface water drainage system.
Yes. A sump unit (also called a sand trap or silt bucket) should be installed at each outlet point. It sits below the channel invert and collects debris, leaves and sediment before they enter the underground drainage pipe. This prevents blockages downstream. Sump units have a removable bucket that should be cleaned out periodically.