Part E Wall & Floor Sound Reduction

The separating wall and floor constructions Approved Document E lists, with the paragraph each one comes from, and the Robust Details references currently published. No decibel rating is quoted per construction, because Approved Document E attaches none to any of them.

No decibel rating is given per construction below, and that is deliberate. Approved Document E attaches no decibel rating to any separating wall or floor. Its Sections 2 and 3 give specifications, and state that a construction built correctly to one of them should achievethe Table 1a values, which are DnT,w + Ctr and L'nT,w measured between the finished rooms. Until August 2026 this page printed laboratory Rw and Ln,w ranges beside each construction. They were removed because no published source for them could be found: they are not in Approved Document E, Robust Details Ltd quotes no laboratory rating for its details anywhere in its public material, and the manufacturer figures that do exist are single tested values for one named proprietary system rather than ranges for a generic construction type. A range with nothing behind it is worse than no range at all, particularly beside a compliance target it cannot be compared with. Use the paragraph numbers below to read what Approved Document E specifies, then confirm performance by pre-completion testing under Regulation 41, or on a new-build house or building containing flats by notifying a Robust Detail. To check a build against the constructions Approved Document E actually lists, use the Part E Sound Calculator.

Separating Wall Types (AD E Section 2)

Separating Wall Types (AD E Section 2)
Wall TypeConstructionAD E paragraph
Type 1: Solid masonryDense block or in-situ concrete, min. 415 kg/m² including plaster (brick 375 kg/m²), 13 mm plaster each side2.33 to 2.35
Type 2: Cavity masonryTwo block leaves, min. 50 mm cavity (75 mm for types 2.2 to 2.4), tie type A, plaster or plasterboard finish2.69 to 2.72
Type 3: Masonry between independent panelsSolid or cavity masonry core with independent panels each side, min. 20 kg/m² per panel, not fixed to the core2.105 to 2.107
Type 4: Framed wall with absorbent materialDouble leaf timber frames, min. 200 mm between inside lining faces, mineral wool, 2 x plasterboard each face. AD E describes a timber frame only; for steel it says to seek the manufacturer's advice2.147

Separating Floor Types (AD E Section 3)

Separating Floor Types (AD E Section 3)
Floor TypeConstructionAD E paragraph
Type 1: Concrete base with ceiling and soft floor coveringSlab or planks min. 365 kg/m² including any bonded screed, soft floor covering essential, ceiling treatment C (1.1C) or B (1.2B)3.29 and 3.30
Type 2: Concrete base with ceiling and floating floorSlab min. 300 kg/m² with floating floor (a), (b) or (c) on a resilient layer, ceiling treatment C (2.1C) or B (2.2B). Para 3.68 prints the mass for floor type 2.2B as 300g/m², which cannot be right at those units; agree the intended value with building control3.67 and 3.68
Type 3: Timber frame base with ceiling and platform floorTimber joists, deck min. 20 kg/m², platform floor on mineral wool 60 to 100 kg/m³, ceiling treatment A. AD E describes ONE timber separating floor, 3.1A; there is no engineered-joist variant in the document3.100 to 3.102

Robust Details references

These are Robust Details Ltd references, not Approved Document E references. Approved Document E names the scheme at para 0.2 and in Annex E but reproduces none of its details, so no code of this form appears anywhere in the document. Robust Details Ltd quotes no laboratory Rw or Ln,w rating for its details anywhere in its public material, including the per-detail pages and the site checklists, so a code is a construction to build to and not a decibel figure. The Robust Details Handbook is the authority for what each code stands for.

The series below are the details for which Robust Details Ltd publishes a site checklist at robustdetails.com/support/downloads, read on 5 August 2026. The Handbook itself is in its fourth edition, most recently amended by the April 2026 update, and is available to account holders rather than published openly. Note that the numbering is not continuous, because details are withdrawn: the April 2026 changes sheet records E-WM-16 as withdrawn from further registrations, and E-WM-7, E-WM-8, E-WM-14, E-WM-15 and E-FC-3 are also absent from the current checklist library. Check the Handbook before specifying or notifying any code, and confirm it is still open for registration.

Robust Details references
RD seriesRobust Details categoryPublished as at 5 August 2026
E-WMSeparating walls, loadbearing masonry30 details: E-WM-1 to 6, 9 to 13, and 17 to 35
E-WTSeparating walls, timber frame4 details: E-WT-1 to E-WT-4
E-WSSeparating walls, steel frame6 details: E-WS-1 to E-WS-6
E-FCSeparating floors, concrete, for loadbearing masonry18 details: E-FC-1, E-FC-2, and E-FC-4 to E-FC-19
E-FTSeparating floors, timber8 details: E-FT-1 to E-FT-8
E-FSSeparating floors, reinforced concrete and steel frame3 details: E-FS-1 to E-FS-3

Note the two series a shorter list would miss. Approved Document E has no deemed-to-satisfy construction for a steel framed separating wall, and para 2.141 says to seek the manufacturer's advice, but Robust Details publishes six (E-WS). Reinforced concrete and steel frame floors have their own series (E-FS) separate from the concrete floors used with loadbearing masonry (E-FC).

Scotland & Northern Ireland

Scotland works to Section 5 (Noise) of the Building Standards Technical Handbook, and its figures are not comparable with the Table 1a values above, because it uses a different quantity. Table 5.1 at clause 5.1.2 of the January 2025 domestic handbook sets a minimum airborne 56 DnT,w and a maximum impact 56 L'nT,w for new build and conversions other than traditional buildings, and 53 DnT,w and 58 L'nT,w for conversions of traditional buildings. DnT,w carries no Ctr term, so 56 in Scotland and 45 in England and Wales are not the same measurement and cannot be read as an 11 dB difference in strictness.

Northern Ireland works to Technical Booklet G 2012, whose Table 1a carries the same figures as Approved Document E: minimum airborne 45 dB DnT,w + Ctr for new dwellings and 43 dB where the dwelling is formed by a material change of use, with maximum impact 62 dB L'nT,w on new floors and stairs and 64 dB on those formed by a material change of use.

Robust Details is not an England and Wales only scheme. Scotland has a separate Robust Details scheme with its own handbook and its own detail references, so the codes above do not apply there, and clause 5.1.2 states that if all the scheme rules are followed then post-completion testing is not necessary. Northern Ireland accepts details from the set approved and published by Robust Details Ltd under Technical Booklet G para 0.14 and Appendix D, on the same shape of exception as England and Wales: new-build houses and buildings containing flats and maisonettes, a valid notification given to the district council, and work that complies with the detail specified in the notification.

Related Calculators

Use the Sound Insulation Calculator for acoustic performance estimates. See the Part E Acoustic Ratings page for the performance targets. See also the Part E Sound Calculator.

Always check the latest edition of Approved Documents on the Planning Portal (planningportal.co.uk) as regulations are updated periodically.